| Excel | Excel NE | Excelet | Excel SM | Mobile | Centrex 2000 | Centrex 2000 NE | Centrex 2000 A/F | Centrex 2000 A/F NE | Centrex 3000 | Centrex 3000 NE | Centrex 3000 A/F | Centrex 3000 A/F NE | Classic 1000-2 2 chambers |
Classic 1000-3 3 chambers |
Classic 750-2 2 chambers |
Classic 750-3 3 chambers |
Compact NL 2 2 chambers |
Compact NL 3 3 chambers |
Classic 650 -2 2 chambers |
Classic 650 -3 3 chambers |
|
| Composting Capacity | |||||||||||||||||||||
| Number of Equivalent People (full-time use) | 3-4 | 2-3 | 1 | 1-2 | 1-2 | 4-6 | 3-5 | 4-6 | 3-5 | 6-8 | 5-7 | 5-7 | 5-7 | 3-4 | 5-6 | 2-3 | 4 | 1 | 2 | 1 | 2 |
| Electrical Components | |||||||||||||||||||||
| Fan Watts (required or optional hook-up) | 35 req. | 2 opt. | 2 | 35 req. | 4 req. | 35 req. | 2 opt. | 35 req. | 2 opt. | 35 req. | 2 opt. | 35 req. | 2 opt. | 5 req. | 5 rq. | 2 req. | 2 req. | 2 req. | 2 req. | 2 req. | 2 req. |
| Average Heater Watts (heater on 50%) | 150 | N/A | N/A | 125 | 63 | 200 | N/A | 200 | N/A | 215 | N/A | 215 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| Unit Dimensions cms | |||||||||||||||||||||
| Height (composter only) | 84 | 80 | 62 | 72 | 71 | 71 | 67 | 71 | 67 | 77 | 74 | 77 | 74 | 80 | 80 | 60 | 60 | 55 | 55 | 55 | 55 |
| Depth | 84 | 82.5 | 72 | 84 | 57 | 68.5 | 67 | 68.5 | 67 | 70 | 70 | 70 | 70 | 80 | 80 | 60 | 60 | 45 | 45 | 45 | 45 |
| Width | 57 | 57 | 52 | 54.5 | 49.5 | 115.5 | 115.5 | 115.5 | 115.5 | 180 | 180 | 180 | 180 | 80 | 80 | 60 | 60 | 45 | 45 | 45 | 45 |
| Waste Chute Diameter | N/A | N/A | N/A | N/A | N/A | 9 | 9 | 25 | 25 | 9 | 9 | 25 | 25 | 25 | 25 | 25 | 25 | N/A | N/A | 25 | 25 |
| Vent & Drains cms | |||||||||||||||||||||
| Vent pipe | 5 | 10 | 10 | 5 | 7.5 | 5 | 10 | 5 | 10 | 5 | 10 | 5 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Drains (required or optional hook-up) | 1.2 opt. | 2.4 req. | 1.9 | 1.2 opt. | 2.4 req. | req. | req. | opt. | req. | req. | req. | opt. | req. | 2.5 | 2.5 | 1.9 | 1.9 | 1.9 | 1.9 | 1.9 | 1.9 |
| Weight (Kgs) | |||||||||||||||||||||
| Shipping Weight | 45.5 | 43 | 41 | 36 | 54 | 49 | 56 | 52 | 78 | 75 | 81 | 77 | 35 | 35 | 20 | 20 | 12 | 12 | 18 | 18 | |
| Shipping Carton Dimensions cms | |||||||||||||||||||||
| Height | 91.5 | 91.5 | 77.5 | 94 | 76 | 76 | 91.5 | 91.5 | 84 | 84 | 84 | 84 | 80 x 2 | 80 x 3 | 60 x 2 | 60 x 3 | 55 x 2 | 55 x 3 | 55 x 2 | 55 x 3 | |
| Length | 90 | 90 | 90 | 73.5 | 119 | 119 | 119 | 119 | 153.5 | 153.5 | 153.5 | 153.5 | 80 x 2 | 80 x 3 | 60 x 2 | 60 x 3 | 45 x 2 | 45 x 3 | 45 x 2 | 45 x 3 | |
| Width | 71 | 71 | 71 | 56 | 72 | 72 | 72 | 72 | 71 | 71 | 71 | 71 | 80 x 2 | 80 x 3 | 60 x 2 | 60 x 3 | 45 x 2 | 45 x 3 | 45 x 2 | 45 x 3 | |
| Rough-in Measurements cms | |||||||||||||||||||||
| Depth required to remove drawer | 117 | 117 | N/A | 114 | 79 | 114 | 114 | 114 | 114 | 116 | 116 | 116 | 116 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| Req. depth to centre of chute from wall | N/A | N/A | N/A | N/A | N/A | 27 | 27 | 30 | 30 | 27 | 27 | 30 | 30 | 30 | 30 | 30 | 30 | N/A | N/A | 30 | 30 |
| Min. vertical gap under bathroom floor | N/A | N/A | N/A | N/A | N/A | 80 | 80 | 100 | 100 | 80 | 80 | 100 | 100 | 100 | 100 | 75 | 75 | N/A | N/A | 65 | 65 |
| Approvals and Certification | |||||||||||||||||||||
| Australian standards 1546.2 certification | YES | YES | YES | N/A | YES | YES | YES | YES | YES | YES | YES | YES | YES | YES | YES | YES | NO | NO | NO | NO | |
| State approvals | ALL | QLD/NSW/NT | NO | QLD/NSW | N/A | QLD/NSW/NT | QLD/NSW/NT | QLD/NSW/NT/VIC | QLD/NSW/NT | QLD/NSW/NT/SA | QLD/NSW/NT | QLD/NSW/NT/VIC | QLD/NSW/NT | ALL | ALL | ALL | ALL | NO | NO | QLD Only | QLD Only |