Excel Excel NE Excel SM Mobile Centrex 2000 Centrex 2000 NE Centrex 2000 A/F Centrex 2000 A/F NE Centrex 3000 Centrex 3000 NE Centrex 3000 A/F Centrex 3000 A/F NE Classic 1000-2
2 chambers
Classic 1000-3
3 chambers
Classic 750-2
2 chambers
Classic 750-3
3 chambers
Compact NL 2
2 chambers
Compact NL 3
3 chambers
Classic 650 -2
2 chambers
Classic 650 -3
3 chambers
Composting Capacity                                        
Number of Equivalent People (full-time use) 3-4 2-3 1-2 1-2 4-6 3-5 4-6 3-5 6-8 5-7 5-7 5-7 3-4 5-6 2-3 4 1 2 1 2
Electrical                                        
Fan Watts (required or optional hook-up) 35 req. 2 opt. 35 req. 4 req. 35 req. 2 opt. 35 req. 2 opt. 35 req. 2 opt. 35 req. 2 opt. 5 req. 5 rq. 2 req. 2 req. 2 req. 2 req. 2 req. 2 req.
Average Heater Watts (heater on 50%) 150 N/A 125 63 200 N/A 200 N/A 215 N/A 215 N/A N/A N/A N/A N/A N/A N/A N/A N/A
Unit Dimensions cms                                        
Height (composter only) 84 80 72 71 71 67 71 67 77 74 77 74 80 80 60 60 55 55 55 55
Depth 84 82.5 84 57 68.5 67 68.5 67 70 70 70 70 80 80 60 60 45 45 45 45
Width 57 57 54.5 49.5 115.5 115.5 115.5 115.5 180 180 180 180 80 80 60 60 45 45 45 45
Waste Chute Diameter N/A N/A N/A N/A 9 9 25 25 9 9 25 25 25 25 25 25 N/A N/A 25 25
Vent & Drains cms                                        
Vent pipe 5 10 5 7.5 5 10 5 10 5 10 5 10 10 10 10 10 10 10 10 10
Drains (required or optional hook-up) 1.2 opt. 2.4 req. 1.2 opt. 2.4 req. req. req. opt. req. req. req. opt. req. 2.5 2.5 1.9 1.9 1.9 1.9 1.9 1.9
Weight (Kgs)                                        
Shipping Weight 45.5 43 41 36 54 49 56 52 78 75 81 77 35 35 20 20 12 12 18 18
Shipping Carton Dimensions cms                                        
Height 91.5 91.5 77.5 94 76 76 91.5 91.5 84 84 84 84 80 x 2 80 x 3 60 x 2 60 x 3 55 x 2 55 x 3 55 x 2 55 x 3
Length 90 90 90 73.5 119 119 119 119 153.5 153.5 153.5 153.5 80 x 2 80 x 3 60 x 2 60 x 3 45 x 2 45 x 3 45 x 2 45 x 3
Width 71 71 71 56 72 72 72 72 71 71 71 71 80 x 2 80 x 3 60 x 2 60 x 3 45 x 2 45 x 3 45 x 2 45 x 3
Rough-in Measurements cms                                        
Depth required to remove drawer 117 117 114 79 114 114 114 114 116 116 116 116 N/A N/A N/A N/A N/A N/A N/A N/A
Req. depth to centre of chute from wall N/A N/A N/A N/A 27 27 30 30 27 27 30 30 30 30 30 30 N/A N/A 30 30
Min. vertical gap under bathroom floor N/A N/A N/A N/A 80 80 100 100 80 80 100 100 100 100 75 75 N/A N/A 65 65
Approvals and Certification                                        
Australian standards 1546.2 certification YES YES YES N/A YES YES YES YES YES YES YES YES YES YES YES YES NO NO NO NO
State approvals ALL QLD/NSW QLD/NSW N/A QLD/NSW QLD/NSW QLD/NSW QLD/NSW QLD/NSW QLD/NSW QLD/NSW QLD/NSW ALL ALL ALL ALL NO NO QLD Only QLD Only